{"product_id":"bticino-f84-4-40-bticino-g44-63as-4-pole-rcbo-assembly-40a-curve-c-400v-ac-idn-0-3a-type-ac-6ka","title":"BTicino F84\/4\/40 + BTicino G44\/63AS – 4-Pole RCBO Assembly 40A Curve C | 400V AC | Idn 0.3A | Type AC | 6kA","description":"\u003cp data-start=\"186\" data-end=\"464\"\u003eThis assembly consists of a \u003cstrong data-start=\"214\" data-end=\"273\"\u003eBTicino F84\/4\/40 4-pole miniature circuit breaker (MCB)\u003c\/strong\u003e combined with a \u003cstrong data-start=\"290\" data-end=\"346\"\u003eBTicino G44\/63AS residual current block (RCD module)\u003c\/strong\u003e, forming a complete \u003cstrong data-start=\"367\" data-end=\"426\"\u003emagnetothermal and residual current protection solution\u003c\/strong\u003e for three-phase systems with neutral.\u003c\/p\u003e\n\u003cp data-start=\"466\" data-end=\"493\"\u003eThe combined unit provides:\u003c\/p\u003e\n\u003cul data-start=\"495\" data-end=\"595\"\u003e\n\u003cli data-start=\"495\" data-end=\"518\"\u003e\n\u003cp data-start=\"497\" data-end=\"518\"\u003eOverload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"519\" data-end=\"547\"\u003e\n\u003cp data-start=\"521\" data-end=\"547\"\u003eShort-circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"548\" data-end=\"595\"\u003e\n\u003cp data-start=\"550\" data-end=\"595\"\u003eEarth leakage (residual current) protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"597\" data-end=\"746\"\u003eIt is particularly suitable for advanced residential switchboards and industrial distribution panels where reliable four-pole protection is required.\u003c\/p\u003e\n\u003cp data-start=\"748\" data-end=\"956\"\u003eWith a \u003cstrong data-start=\"755\" data-end=\"808\"\u003erated residual operating current of 300 mA (0.3A)\u003c\/strong\u003e, this device is especially appropriate as a \u003cstrong data-start=\"853\" data-end=\"888\"\u003emain upstream protection device\u003c\/strong\u003e, contributing to fire prevention in the event of insulation faults.\u003c\/p\u003e\n\u003chr data-start=\"958\" data-end=\"961\"\u003e\n\u003ch2 data-start=\"963\" data-end=\"995\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003ch3 data-start=\"997\" data-end=\"1035\"\u003e🔹 Miniature Circuit Breaker (MCB)\u003c\/h3\u003e\n\u003cp data-start=\"1037\" data-end=\"1255\"\u003e\u003cstrong data-start=\"1037\" data-end=\"1047\"\u003eBrand:\u003c\/strong\u003e BTicino\u003cbr data-start=\"1055\" data-end=\"1058\"\u003e\u003cstrong data-start=\"1058\" data-end=\"1068\"\u003eModel:\u003c\/strong\u003e F84\/4\/40\u003cbr data-start=\"1077\" data-end=\"1080\"\u003e\u003cstrong data-start=\"1080\" data-end=\"1100\"\u003eNumber of poles:\u003c\/strong\u003e 4P (3P + N)\u003cbr data-start=\"1112\" data-end=\"1115\"\u003e\u003cstrong data-start=\"1115\" data-end=\"1138\"\u003eRated current (In):\u003c\/strong\u003e 40 A\u003cbr data-start=\"1143\" data-end=\"1146\"\u003e\u003cstrong data-start=\"1146\" data-end=\"1165\"\u003eTripping curve:\u003c\/strong\u003e C\u003cbr data-start=\"1167\" data-end=\"1170\"\u003e\u003cstrong data-start=\"1170\" data-end=\"1188\"\u003eRated voltage:\u003c\/strong\u003e 400 V AC\u003cbr data-start=\"1197\" data-end=\"1200\"\u003e\u003cstrong data-start=\"1200\" data-end=\"1222\"\u003eBreaking capacity:\u003c\/strong\u003e 6 kA\u003cbr data-start=\"1227\" data-end=\"1230\"\u003e\u003cstrong data-start=\"1230\" data-end=\"1244\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/p\u003e\n\u003chr data-start=\"1257\" data-end=\"1260\"\u003e\n\u003ch3 data-start=\"1262\" data-end=\"1304\"\u003e🔹 Residual Current Block (RCD Module)\u003c\/h3\u003e\n\u003cp data-start=\"1306\" data-end=\"1512\"\u003e\u003cstrong data-start=\"1306\" data-end=\"1316\"\u003eModel:\u003c\/strong\u003e G44\/63AS\u003cbr data-start=\"1325\" data-end=\"1328\"\u003e\u003cstrong data-start=\"1328\" data-end=\"1356\"\u003eRated current supported:\u003c\/strong\u003e 63 A\u003cbr data-start=\"1361\" data-end=\"1364\"\u003e\u003cstrong data-start=\"1364\" data-end=\"1407\"\u003eRated residual operating current (Idn):\u003c\/strong\u003e 0.3 A (300 mA)\u003cbr data-start=\"1422\" data-end=\"1425\"\u003e\u003cstrong data-start=\"1425\" data-end=\"1434\"\u003eType:\u003c\/strong\u003e AC\u003cbr data-start=\"1437\" data-end=\"1440\"\u003e\u003cstrong data-start=\"1440\" data-end=\"1456\"\u003eTest button:\u003c\/strong\u003e Present\u003cbr data-start=\"1464\" data-end=\"1467\"\u003e\u003cstrong data-start=\"1467\" data-end=\"1489\"\u003eStatus indication:\u003c\/strong\u003e Dedicated blue lever\u003c\/p\u003e\n\u003chr data-start=\"1514\" data-end=\"1517\"\u003e\n\u003ch2 data-start=\"1519\" data-end=\"1539\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1541\" data-end=\"1729\"\u003e✔ Three-phase electrical panels\u003cbr data-start=\"1572\" data-end=\"1575\"\u003e✔ Industrial installations\u003cbr data-start=\"1601\" data-end=\"1604\"\u003e✔ Main distribution lines\u003cbr data-start=\"1629\" data-end=\"1632\"\u003e✔ Feeder protection\u003cbr data-start=\"1651\" data-end=\"1654\"\u003e✔ Commercial buildings\u003cbr data-start=\"1676\" data-end=\"1679\"\u003e✔ Upstream protection of sub-distribution boards\u003c\/p\u003e\n\u003cp data-start=\"1731\" data-end=\"1864\"\u003eThe \u003cstrong data-start=\"1735\" data-end=\"1764\"\u003e300 mA residual threshold\u003c\/strong\u003e makes this device particularly suitable for general fire protection against earth leakage currents.\u003c\/p\u003e\n\u003chr data-start=\"1866\" data-end=\"1869\"\u003e\n\u003ch2 data-start=\"1871\" data-end=\"1899\"\u003e🔒 Protection Functions\u003c\/h2\u003e\n\u003cp data-start=\"1901\" data-end=\"2087\"\u003e✔ Thermal protection against overloads\u003cbr data-start=\"1939\" data-end=\"1942\"\u003e✔ Magnetic protection against short circuits\u003cbr data-start=\"1986\" data-end=\"1989\"\u003e✔ Residual current protection against earth faults\u003cbr data-start=\"2039\" data-end=\"2042\"\u003e✔ Simultaneous disconnection of all 4 poles\u003c\/p\u003e\n\u003chr data-start=\"2089\" data-end=\"2092\"\u003e\n\u003ch2 data-start=\"2094\" data-end=\"2114\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"2116\" data-end=\"2267\"\u003e\n\u003cli data-start=\"2116\" data-end=\"2137\"\u003e\n\u003cp data-start=\"2118\" data-end=\"2137\"\u003eDIN rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2138\" data-end=\"2168\"\u003e\n\u003cp data-start=\"2140\" data-end=\"2168\"\u003eScrew terminal connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2169\" data-end=\"2212\"\u003e\n\u003cp data-start=\"2171\" data-end=\"2212\"\u003eCompatible with BTicino modular systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2213\" data-end=\"2267\"\u003e\n\u003cp data-start=\"2215\" data-end=\"2267\"\u003eDirect integration of MCB + residual current block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2269\" data-end=\"2272\"\u003e\n\u003ch2 data-start=\"2274\" data-end=\"2291\"\u003e📦 Condition\u003c\/h2\u003e\n\u003cp data-start=\"2293\" data-end=\"2423\"\u003eUsed product in good cosmetic condition.\u003cbr data-start=\"2333\" data-end=\"2336\"\u003eElectrical functionality not tested at this stage.\u003cbr data-start=\"2386\" data-end=\"2389\"\u003eSupplied as shown in the images.\u003c\/p\u003e\n\u003chr data-start=\"2425\" data-end=\"2428\"\u003e\n\u003ch2 data-start=\"2430\" data-end=\"2447\"\u003e✅ Advantages\u003c\/h2\u003e\n\u003cp data-start=\"2449\" data-end=\"2645\"\u003e✔ Compact combined protection system\u003cbr data-start=\"2485\" data-end=\"2488\"\u003e✔ Complete 4-pole protection\u003cbr data-start=\"2516\" data-end=\"2519\"\u003e✔ High BTicino build quality\u003cbr data-start=\"2547\" data-end=\"2550\"\u003e✔ Suitable as a three-phase main breaker\u003cbr data-start=\"2590\" data-end=\"2593\"\u003e✔ Integrated TEST button for periodic verification\u003c\/p\u003e","brand":"BTicino","offers":[{"title":"Default Title","offer_id":53426504237389,"sku":null,"price":60.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_4912.jpg?v=1772013992","url":"https:\/\/greenenergy-repair.com\/de\/products\/bticino-f84-4-40-bticino-g44-63as-4-pole-rcbo-assembly-40a-curve-c-400v-ac-idn-0-3a-type-ac-6ka","provider":"Green Energy","version":"1.0","type":"link"}