{"product_id":"abb-es500c-500-a-current-transducer-10140153","title":"ABB ES500C | 500 A Current Transducer | 10140153","description":"\u003ch3\u003e\n\u003cspan\u003e📝 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eUsed product.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eOriginal \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eABB ES500C current transducer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, identified by the markings on the housing: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eES500C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, code \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10140153\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the specifications \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIPN 500 A – 600 V – VA ±12…±24 V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThis is a closed-loop Hall effect current sensor designed to measure direct, alternating and pulsed currents while maintaining galvanic isolation between the primary power circuit and the secondary measurement circuit.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe conductor being measured passes through the sensor's central opening. The device generates a secondary signal proportional to the detected current, suitable for compatible electronic control, monitoring and regulation circuits.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe construction includes an insulating housing, an opening for the primary conductor, a mounting flange and a secondary electrical connector.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e⚙️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMain Specifications\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ABB\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eModel:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ES500C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eVisible code:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10140153\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eType:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Hall effect current transducer\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTechnology:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Closed-loop compensation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRated primary current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 500 A RMS\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMeasurement range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to ±800 A, according to the ABB catalogue\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNominal secondary signal:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 100 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower supply:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ±12–24 V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSpecified accuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately ±0.6% at rated current, under the conditions specified by ABB\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBandwidth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to 100 kHz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eResponse time:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ≤ 1 µs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOperating temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e −20°C to +70°C, according to the ABB series catalogue\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNominal aperture diameter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 31 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eApproximate catalogue weight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 210 g\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMounting:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Panel mounting through fixing holes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔌 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMain Functions\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures alternating, direct and pulsed currents.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConverts primary current into a proportional secondary signal.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides galvanic isolation between the power circuit and the measurement circuit.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTransmits the signal to electronic monitoring and control systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDetects current in industrial and power electronics applications.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🛠️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eInverters and static converters.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectric drives and motor control systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial power supplies.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnergy conversion systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUninterruptible power supplies (UPS).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCurrent measurement and control equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🧩 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe transducer is intended for equipment designed for sensors with equivalent specifications.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eBefore replacement, verify:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eThe exact transducer model.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRated current and measurement range.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRequired power supply.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnector type and terminal arrangement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDimensions and mounting points.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSecondary circuit characteristics.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCompatibility with a specific inverter or machine cannot be guaranteed without comparison with the equipment's technical documentation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e💡 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAC and DC current measurement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGalvanic isolation between primary and secondary circuits.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGood accuracy and fast response.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWide bandwidth.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting flange and through-hole design.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOriginal ABB replacement component for compatible equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🛡️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eProduct Condition\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUsed product with surface marks and signs of use visible in the photographs.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eElectrical functionality has not been verified through instrument testing. Checking the device before installation is recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e📦 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePackage Contents\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cspan\u003e1 ABB ES500C current transducer.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCables, power supplies and other accessories not visible in the photographs are not included.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🟢 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSummary\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eABB ES500C 500 A RMS current transducer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, featuring closed-loop Hall effect technology, galvanic isolation and a ±12–24 V DC power supply. Designed for industrial systems, inverters and power converters, subject to verification of electrical and mechanical compatibility.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":55227955741005,"sku":null,"price":55.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7264.jpg?v=1793291061","url":"https:\/\/greenenergy-repair.com\/de\/products\/abb-es500c-500-a-current-transducer-10140153","provider":"Green Energy","version":"1.0","type":"link"}