{"product_id":"solar-king-119-sirs-002-rs485-modbus-communication-board-slk-series-inverter-interface-module","title":"Solar King 119-SIRS-002 – RS485 Modbus Communication Board | SLK Series Inverter Interface Module","description":"\u003cp data-start=\"145\" data-end=\"363\"\u003eThe \u003cstrong data-start=\"149\" data-end=\"176\"\u003eSolar King 119-SIRS-002\u003c\/strong\u003e is an industrial \u003cstrong data-start=\"194\" data-end=\"245\"\u003eRS485 communication module with Modbus protocol\u003c\/strong\u003e, designed for installation in the expansion slot of \u003cstrong data-start=\"298\" data-end=\"346\"\u003eSolar King SLK series photovoltaic inverters\u003c\/strong\u003e (e.g. SLK-6000).\u003c\/p\u003e\n\u003cp data-start=\"365\" data-end=\"544\"\u003eThese inverters support optional communication cards (RS485 or SNMP), allowing integration into monitoring systems and enabling \u003cstrong data-start=\"493\" data-end=\"527\"\u003eremote supervision and control\u003c\/strong\u003e of the PV plant.\u003c\/p\u003e\n\u003chr data-start=\"546\" data-end=\"549\"\u003e\n\u003ch3 data-start=\"551\" data-end=\"571\"\u003e⚙️ Main Function\u003c\/h3\u003e\n\u003cp data-start=\"572\" data-end=\"590\"\u003eThis board allows:\u003c\/p\u003e\n\u003cul data-start=\"591\" data-end=\"735\"\u003e\n\u003cli data-start=\"591\" data-end=\"636\"\u003eTransmission of inverter operational data\u003c\/li\u003e\n\u003cli data-start=\"637\" data-end=\"682\"\u003eConnection to external monitoring systems\u003c\/li\u003e\n\u003cli data-start=\"683\" data-end=\"735\"\u003eIntegration into industrial supervision networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"737\" data-end=\"836\"\u003e👉 It effectively transforms the inverter into a \u003cstrong data-start=\"786\" data-end=\"834\"\u003eremotely monitorable and controllable device\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"838\" data-end=\"841\"\u003e\n\u003ch3 data-start=\"843\" data-end=\"874\"\u003e🔌 Interfaces \u0026amp; Connections\u003c\/h3\u003e\n\u003cul data-start=\"875\" data-end=\"1135\"\u003e\n\u003cli data-start=\"875\" data-end=\"927\"\u003e\n\u003cstrong data-start=\"877\" data-end=\"901\"\u003e2 × RJ45 RS485 ports\u003c\/strong\u003e → serial bus connection\u003c\/li\u003e\n\u003cli data-start=\"928\" data-end=\"999\"\u003e\n\u003cstrong data-start=\"930\" data-end=\"971\"\u003eRS485 terminal block (R+, R-, T+, T-)\u003c\/strong\u003e → direct wired connection\u003c\/li\u003e\n\u003cli data-start=\"1000\" data-end=\"1070\"\u003e\n\u003cstrong data-start=\"1002\" data-end=\"1016\"\u003eDIP switch\u003c\/strong\u003e → address and communication parameter configuration\u003c\/li\u003e\n\u003cli data-start=\"1071\" data-end=\"1114\"\u003e\n\u003cstrong data-start=\"1073\" data-end=\"1088\"\u003eStatus LEDs\u003c\/strong\u003e → operation diagnostics\u003c\/li\u003e\n\u003cli data-start=\"1115\" data-end=\"1135\"\u003e\u003cstrong data-start=\"1117\" data-end=\"1133\"\u003eRESET button\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1137\" data-end=\"1140\"\u003e\n\u003ch3 data-start=\"1142\" data-end=\"1171\"\u003e🧠 Communication Protocol\u003c\/h3\u003e\n\u003cul data-start=\"1172\" data-end=\"1329\"\u003e\n\u003cli data-start=\"1172\" data-end=\"1200\"\u003eProtocol: \u003cstrong data-start=\"1184\" data-end=\"1198\"\u003eModbus RTU\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1201\" data-end=\"1270\"\u003ePhysical interface: \u003cstrong data-start=\"1223\" data-end=\"1268\"\u003eRS485 (differential, industrial standard)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1271\" data-end=\"1329\"\u003eCommunication type: \u003cstrong data-start=\"1293\" data-end=\"1327\"\u003eMulti-device BUS (half-duplex)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1331\" data-end=\"1417\"\u003e👉 RS485 ensures \u003cstrong data-start=\"1348\" data-end=\"1388\"\u003ereliable long-distance communication\u003c\/strong\u003e in industrial environments\u003c\/p\u003e\n\u003chr data-start=\"1419\" data-end=\"1422\"\u003e\n\u003ch3 data-start=\"1424\" data-end=\"1454\"\u003e📊 Monitoring Capabilities\u003c\/h3\u003e\n\u003cp data-start=\"1455\" data-end=\"1508\"\u003eThrough software or dataloggers, the system can read:\u003c\/p\u003e\n\u003cul data-start=\"1509\" data-end=\"1646\"\u003e\n\u003cli data-start=\"1509\" data-end=\"1540\"\u003eEnergy production (\u003cstrong data-start=\"1530\" data-end=\"1537\"\u003ekWh\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"1541\" data-end=\"1572\"\u003eInstantaneous power (\u003cstrong data-start=\"1564\" data-end=\"1569\"\u003eW\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"1573\" data-end=\"1591\"\u003eDC\/AC voltages\u003c\/li\u003e\n\u003cli data-start=\"1592\" data-end=\"1604\"\u003eCurrents\u003c\/li\u003e\n\u003cli data-start=\"1605\" data-end=\"1624\"\u003eInverter status\u003c\/li\u003e\n\u003cli data-start=\"1625\" data-end=\"1646\"\u003eAlarms and faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1648\" data-end=\"1651\"\u003e\n\u003ch3 data-start=\"1653\" data-end=\"1672\"\u003e🔗 Applications\u003c\/h3\u003e\n\u003cul data-start=\"1673\" data-end=\"1835\"\u003e\n\u003cli data-start=\"1673\" data-end=\"1707\"\u003ePhotovoltaic system monitoring\u003c\/li\u003e\n\u003cli data-start=\"1708\" data-end=\"1746\"\u003eIntegration with \u003cstrong data-start=\"1727\" data-end=\"1744\"\u003eSCADA systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1747\" data-end=\"1785\"\u003eConnection to external dataloggers\u003c\/li\u003e\n\u003cli data-start=\"1786\" data-end=\"1835\"\u003eCentralized supervision of multiple inverters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1837\" data-end=\"1840\"\u003e\n\u003ch3 data-start=\"1842\" data-end=\"1862\"\u003e🏭 Compatibility\u003c\/h3\u003e\n\u003cp data-start=\"1863\" data-end=\"1934\"\u003eDesigned for \u003cstrong data-start=\"1876\" data-end=\"1922\"\u003eSolar King \/ Powercom SLK series inverters\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"1935\" data-end=\"1986\"\u003e\n\u003cli data-start=\"1935\" data-end=\"1947\"\u003eSLK-2000\u003c\/li\u003e\n\u003cli data-start=\"1948\" data-end=\"1960\"\u003eSLK-3000\u003c\/li\u003e\n\u003cli data-start=\"1961\" data-end=\"1973\"\u003eSLK-4000\u003c\/li\u003e\n\u003cli data-start=\"1974\" data-end=\"1986\"\u003eSLK-6000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1988\" data-end=\"2067\"\u003e👉 Specifically built for the \u003cstrong data-start=\"2018\" data-end=\"2049\"\u003einternal communication slot\u003c\/strong\u003e of these models\u003c\/p\u003e\n\u003chr data-start=\"2069\" data-end=\"2072\"\u003e\n\u003ch3 data-start=\"2074\" data-end=\"2099\"\u003e🧩 Technical Features\u003c\/h3\u003e\n\u003cul data-start=\"2100\" data-end=\"2291\"\u003e\n\u003cli data-start=\"2100\" data-end=\"2140\"\u003eCommunication: \u003cstrong data-start=\"2117\" data-end=\"2138\"\u003eRS485 half-duplex\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2141\" data-end=\"2169\"\u003eProtocol: \u003cstrong data-start=\"2153\" data-end=\"2167\"\u003eModbus RTU\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2170\" data-end=\"2203\"\u003eConfiguration: \u003cstrong data-start=\"2187\" data-end=\"2201\"\u003eDIP switch\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2204\" data-end=\"2248\"\u003eInstallation: \u003cstrong data-start=\"2220\" data-end=\"2246\"\u003ePlug-in internal board\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2249\" data-end=\"2291\"\u003ePower supply: \u003cstrong data-start=\"2265\" data-end=\"2289\"\u003eProvided by inverter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2293\" data-end=\"2296\"\u003e\n\u003ch3 data-start=\"2298\" data-end=\"2320\"\u003e⚠️ When It Is Used\u003c\/h3\u003e\n\u003cul data-start=\"2321\" data-end=\"2507\"\u003e\n\u003cli data-start=\"2321\" data-end=\"2376\"\u003eTo enable remote monitoring via PC or cloud systems\u003c\/li\u003e\n\u003cli data-start=\"2377\" data-end=\"2437\"\u003eTo connect multiple inverters in a communication network\u003c\/li\u003e\n\u003cli data-start=\"2438\" data-end=\"2507\"\u003eTo integrate with energy management or industrial control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2509\" data-end=\"2512\"\u003e\n\u003ch3 data-start=\"2514\" data-end=\"2538\"\u003e📦 Product Condition\u003c\/h3\u003e\n\u003cul data-start=\"2539\" data-end=\"2644\"\u003e\n\u003cli data-start=\"2539\" data-end=\"2580\"\u003eElectronic board (used \/ refurbished)\u003c\/li\u003e\n\u003cli data-start=\"2581\" data-end=\"2606\"\u003eTested (if specified)\u003c\/li\u003e\n\u003cli data-start=\"2607\" data-end=\"2644\"\u003eProfessional technical spare part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2646\" data-end=\"2649\"\u003e\n\u003ch3 data-start=\"2651\" data-end=\"2665\"\u003e💡 Summary\u003c\/h3\u003e\n\u003cp data-start=\"2667\" data-end=\"2780\"\u003eThe \u003cstrong data-start=\"2671\" data-end=\"2698\"\u003eSolar King 119-SIRS-002\u003c\/strong\u003e is an essential \u003cstrong data-start=\"2715\" data-end=\"2751\"\u003eRS485 Modbus communication board\u003c\/strong\u003e for SLK inverters, enabling:\u003c\/p\u003e\n\u003cp data-start=\"2782\" data-end=\"2896\"\u003e✔ Remote monitoring\u003cbr data-start=\"2801\" data-end=\"2804\"\u003e✔ Energy data acquisition\u003cbr data-start=\"2829\" data-end=\"2832\"\u003e✔ Inverter diagnostics\u003cbr data-start=\"2854\" data-end=\"2857\"\u003e✔ Integration into industrial systems\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53812213645645,"sku":null,"price":40.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5550.jpg?v=1777567173","url":"https:\/\/greenenergy-repair.com\/cs\/products\/solar-king-119-sirs-002-rs485-modbus-communication-board-slk-series-inverter-interface-module","provider":"Green Energy","version":"1.0","type":"link"}