{"product_id":"sirio-151100-100-0-2-a-current-transformer","title":"SIRIO 151100 | 100\/0.2 A Current Transformer","description":"\u003ch3\u003e\n\u003cspan\u003e📝 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eUsed product.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSIRIO current transformer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, identified by the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100\/0.2 A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e marking and visible code \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e151100 0542\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. This component is designed to measure alternating current by converting the primary current into a proportional secondary current signal while maintaining galvanic isolation between the measured circuit and the measurement circuit.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe device features a central through-hole for the conductor being monitored and Faston-type blade terminals for electrical connections. Its compact construction and insulating housing make it suitable for integration into electrical and electronic equipment.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe SIRIO current transformer product family includes models designed for mains-frequency current measurement in monitoring, control and protection systems. Technical documentation for the corresponding model identifies the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 A \/ 0.2 A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ratio, matching the visible marking.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e⚙️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMain Specifications\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e SIRIO\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eType:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Current transformer\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eVisible code:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 151100 0542\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNominal ratio:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 100 A \/ 0.2 A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRated primary current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 100 A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRated secondary current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0.2 A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTransformation ratio:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 500:1\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInstallation type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Through-hole for the primary conductor\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSecondary connections:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Faston terminals\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e AC current measurement\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInsulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Galvanic isolation between primary and secondary circuits\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The nominal ratio is taken from the component marking. Additional electrical parameters must be verified against the exact datasheet before use.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔌 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMain Functions\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eDetects alternating current flowing through the primary conductor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConverts primary current into a proportional secondary signal.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSends the signal to compatible measurement, monitoring or protection circuits.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides galvanic isolation between the power circuit and the measurement circuit.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🛠️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eElectrical panels and current monitoring systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial electronic equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMeasurement and control circuits.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical consumption monitoring systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible power supplies and electrical conversion equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🧩 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe component may be used in equipment designed for a current transformer with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100\/0.2 A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ratio and compatible secondary connections.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eBefore replacement, verify the transformation ratio, permitted secondary burden, operating frequency, insulation and mechanical dimensions. Matching the ratio alone does not guarantee compatibility with every device.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e💡 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures current without inserting the transformer in series with the primary circuit.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides galvanic isolation between the measured circuit and the measurement circuit.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompact construction with mounting via a bracket or dedicated housing.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecondary connection through Faston terminals.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable as a replacement part for equipment requiring the same electrical and mechanical specifications.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🛡️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eProduct Condition\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUsed product with surface marks and signs of use visible in the photographs. The terminals show signs of oxidation and surface wear.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eOperation has not been instrumentally tested. Electrical testing is recommended before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e📦 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePackage Contents\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cspan\u003e1 SIRIO 100\/0.2 A current transformer.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCables, measuring instruments and other accessories not shown in the photographs are not included.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🟢 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSummary\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSIRIO current transformer with a nominal ratio of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 A \/ 0.2 A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, featuring a through-hole and Faston terminals. Replacement component for AC current measurement and monitoring circuits, to be used after verifying compatibility with the specifications of the target equipment.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sirio Current sensor","offers":[{"title":"Default Title","offer_id":55223538385229,"sku":null,"price":30.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7268.jpg?v=1793272003","url":"https:\/\/greenenergy-repair.com\/cs\/products\/sirio-151100-100-0-2-a-current-transformer","provider":"Green Energy","version":"1.0","type":"link"}