{"product_id":"siemens-5sy41-c1-siemens-5st3010-as-1p-1a-mcb-with-auxiliary-contact-curve-c-230-400v-10ka","title":"Siemens 5SY41 C1 + Siemens 5ST3010 AS – 1P 1A MCB with Auxiliary Contact | Curve C | 230\/400V | 10kA","description":"\u003cp data-start=\"179\" data-end=\"428\"\u003eThis assembly consists of a \u003cstrong data-start=\"207\" data-end=\"259\"\u003eSiemens 5SY41 C1 miniature circuit breaker (MCB)\u003c\/strong\u003e combined with a \u003cstrong data-start=\"276\" data-end=\"323\"\u003eSiemens 5ST3010 AS auxiliary contact module\u003c\/strong\u003e, a configuration commonly used in electrical control panels for circuit protection and status signaling.\u003c\/p\u003e\n\u003cp data-start=\"430\" data-end=\"707\"\u003eThe \u003cstrong data-start=\"434\" data-end=\"463\"\u003eminiature circuit breaker\u003c\/strong\u003e protects the circuit against overloads and short circuits, while the \u003cstrong data-start=\"533\" data-end=\"561\"\u003eauxiliary contact module\u003c\/strong\u003e allows external systems—such as PLCs, relays, monitoring systems, or signal lamps—to detect the breaker’s operational status (ON\/OFF or tripped).\u003c\/p\u003e\n\u003cp data-start=\"709\" data-end=\"903\"\u003eWith a \u003cstrong data-start=\"716\" data-end=\"760\"\u003erated current of 1A and C tripping curve\u003c\/strong\u003e, this device is particularly suitable for protecting \u003cstrong data-start=\"814\" data-end=\"902\"\u003econtrol circuits, instrumentation, industrial automation systems, and command panels\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"905\" data-end=\"1044\"\u003eThe side-mounted auxiliary module provides \u003cstrong data-start=\"948\" data-end=\"995\"\u003enormally open (NO) and normally closed (NC)\u003c\/strong\u003e contacts for signaling and automation functions.\u003c\/p\u003e\n\u003chr data-start=\"1046\" data-end=\"1049\"\u003e\n\u003ch2 data-start=\"1051\" data-end=\"1083\"\u003e⚙️ Technical Specifications\u003c\/h2\u003e\n\u003ch3 data-start=\"1085\" data-end=\"1119\"\u003e🔹 Miniature Circuit Breaker\u003c\/h3\u003e\n\u003cp data-start=\"1121\" data-end=\"1322\"\u003e\u003cstrong data-start=\"1121\" data-end=\"1131\"\u003eBrand:\u003c\/strong\u003e Siemens\u003cbr data-start=\"1139\" data-end=\"1142\"\u003e\u003cstrong data-start=\"1142\" data-end=\"1152\"\u003eModel:\u003c\/strong\u003e 5SY41\u003cbr data-start=\"1158\" data-end=\"1161\"\u003e\u003cstrong data-start=\"1161\" data-end=\"1179\"\u003eRated current:\u003c\/strong\u003e \u003cstrong data-start=\"1180\" data-end=\"1187\"\u003e1 A\u003c\/strong\u003e\u003cbr data-start=\"1187\" data-end=\"1190\"\u003e\u003cstrong data-start=\"1190\" data-end=\"1209\"\u003eTripping curve:\u003c\/strong\u003e \u003cstrong data-start=\"1210\" data-end=\"1215\"\u003eC\u003c\/strong\u003e\u003cbr data-start=\"1215\" data-end=\"1218\"\u003e\u003cstrong data-start=\"1218\" data-end=\"1238\"\u003eNumber of poles:\u003c\/strong\u003e \u003cstrong data-start=\"1239\" data-end=\"1245\"\u003e1P\u003c\/strong\u003e\u003cbr data-start=\"1245\" data-end=\"1248\"\u003e\u003cstrong data-start=\"1248\" data-end=\"1266\"\u003eRated voltage:\u003c\/strong\u003e \u003cstrong data-start=\"1267\" data-end=\"1285\"\u003e230 \/ 400 V AC\u003c\/strong\u003e\u003cbr data-start=\"1285\" data-end=\"1288\"\u003e\u003cstrong data-start=\"1288\" data-end=\"1310\"\u003eBreaking capacity:\u003c\/strong\u003e \u003cstrong data-start=\"1311\" data-end=\"1320\"\u003e10 kA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1324\" data-end=\"1340\"\u003e\u003cstrong data-start=\"1324\" data-end=\"1338\"\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1341\" data-end=\"1380\"\u003e\n\u003cli data-start=\"1341\" data-end=\"1359\"\u003e\n\u003cp data-start=\"1343\" data-end=\"1359\"\u003eIEC \/ EN 60898\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1360\" data-end=\"1380\"\u003e\n\u003cp data-start=\"1362\" data-end=\"1380\"\u003eIEC \/ EN 60947-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1382\" data-end=\"1385\"\u003e\n\u003ch3 data-start=\"1387\" data-end=\"1420\"\u003e🔹 Auxiliary Contact Module\u003c\/h3\u003e\n\u003cp data-start=\"1422\" data-end=\"1625\"\u003e\u003cstrong data-start=\"1422\" data-end=\"1432\"\u003eBrand:\u003c\/strong\u003e Siemens\u003cbr data-start=\"1440\" data-end=\"1443\"\u003e\u003cstrong data-start=\"1443\" data-end=\"1453\"\u003eModel:\u003c\/strong\u003e 5ST3010 AS\u003cbr data-start=\"1464\" data-end=\"1467\"\u003e\u003cstrong data-start=\"1467\" data-end=\"1476\"\u003eType:\u003c\/strong\u003e Auxiliary signaling contact\u003cbr data-start=\"1504\" data-end=\"1507\"\u003e\u003cstrong data-start=\"1507\" data-end=\"1533\"\u003eContact configuration:\u003c\/strong\u003e \u003cstrong data-start=\"1534\" data-end=\"1549\"\u003e1 NO + 1 NC\u003c\/strong\u003e\u003cbr data-start=\"1549\" data-end=\"1552\"\u003e\u003cstrong data-start=\"1552\" data-end=\"1572\"\u003eMaximum voltage:\u003c\/strong\u003e \u003cstrong data-start=\"1573\" data-end=\"1582\"\u003e440 V\u003c\/strong\u003e\u003cbr data-start=\"1582\" data-end=\"1585\"\u003e\u003cstrong data-start=\"1585\" data-end=\"1611\"\u003eRated contact current:\u003c\/strong\u003e \u003cstrong data-start=\"1612\" data-end=\"1625\"\u003eup to 6 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1627\" data-end=\"1630\"\u003e\n\u003ch2 data-start=\"1632\" data-end=\"1652\"\u003e🛠 Installation\u003c\/h2\u003e\n\u003cul data-start=\"1654\" data-end=\"1814\"\u003e\n\u003cli data-start=\"1654\" data-end=\"1688\"\u003e\n\u003cp data-start=\"1656\" data-end=\"1688\"\u003eMounting on \u003cstrong data-start=\"1668\" data-end=\"1686\"\u003e35 mm DIN rail\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1689\" data-end=\"1760\"\u003e\n\u003cp data-start=\"1691\" data-end=\"1760\"\u003eDirect side connection between circuit breaker and auxiliary module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1761\" data-end=\"1814\"\u003e\n\u003cp data-start=\"1763\" data-end=\"1814\"\u003eCompatible with Siemens modular electrical panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1816\" data-end=\"1819\"\u003e\n\u003ch2 data-start=\"1821\" data-end=\"1841\"\u003e🏭 Applications\u003c\/h2\u003e\n\u003cp data-start=\"1843\" data-end=\"1853\"\u003eIdeal for:\u003c\/p\u003e\n\u003cp data-start=\"1855\" data-end=\"2040\"\u003e✔ Industrial automation panels\u003cbr data-start=\"1885\" data-end=\"1888\"\u003e✔ Control circuits\u003cbr data-start=\"1906\" data-end=\"1909\"\u003e✔ Breaker status signaling systems\u003cbr data-start=\"1943\" data-end=\"1946\"\u003e✔ PLC systems\u003cbr data-start=\"1959\" data-end=\"1962\"\u003e✔ Monitoring and supervisory systems\u003cbr data-start=\"1998\" data-end=\"2001\"\u003e✔ Industrial electrical installations\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53474119647565,"sku":null,"price":7.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5026.jpg?v=1772634109","url":"https:\/\/greenenergy-repair.com\/cs\/products\/siemens-5sy41-c1-siemens-5st3010-as-1p-1a-mcb-with-auxiliary-contact-curve-c-230-400v-10ka","provider":"Green Energy","version":"1.0","type":"link"}