{"product_id":"abb-sace-tmax-t3n-250-3-pole-200a-mccb-molded-case-circuit-breaker-with-sor-shunt-trip-auxiliary-contacts-690v-iec-60947-2","title":"ABB SACE Tmax T3N 250 3-Pole 200A MCCB Molded Case Circuit Breaker with SOR Shunt Trip \u0026 Auxiliary Contacts 690V IEC 60947-2","description":"\u003cp data-start=\"147\" data-end=\"575\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eABB SACE Tmax T3N 250\u003c\/strong\u003e is a molded case circuit breaker (MCCB) designed to protect industrial electrical installations against overloads and short circuits. This version is equipped with a shunt trip release (SOR) and auxiliary contacts, making it ideal for automation systems, distribution panels and remote control applications. Manufactured in accordance with IEC 60947-2, it offers high reliability and long service life.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"577\" data-end=\"608\"\u003e\u003cstrong data-start=\"577\" data-end=\"608\"\u003e⚙️ Technical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"610\" data-end=\"880\"\u003eBrand: ABB SACE\u003cbr data-start=\"625\" data-end=\"628\"\u003eSeries: Tmax\u003cbr data-start=\"640\" data-end=\"643\"\u003eModel: T3N 250\u003cbr data-start=\"657\" data-end=\"660\"\u003eType: Molded Case Circuit Breaker (MCCB)\u003cbr data-start=\"700\" data-end=\"703\"\u003eNumber of Poles: 3P\u003cbr data-start=\"722\" data-end=\"725\"\u003eRated Current (In): 200 A\u003cbr data-start=\"750\" data-end=\"753\"\u003eUtilization Category: Cat. A\u003cbr data-start=\"781\" data-end=\"784\"\u003eFrequency: 50–60 Hz\u003cbr data-start=\"803\" data-end=\"806\"\u003eStandard: IEC 60947-2\u003cbr data-start=\"827\" data-end=\"830\"\u003eManufactured in: Italy\u003cbr data-start=\"852\" data-end=\"855\"\u003eSerial Number: BA61076523\u003c\/p\u003e\n\u003cp data-start=\"882\" data-end=\"914\"\u003e\u003cstrong data-start=\"882\" data-end=\"914\"\u003e🔌 Electrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"916\" data-end=\"1042\"\u003eRated Operational Voltage (Ue): 690 V AC\u003cbr data-start=\"956\" data-end=\"959\"\u003eRated Insulation Voltage (Ui): 800 V\u003cbr data-start=\"995\" data-end=\"998\"\u003eRated Impulse Withstand Voltage (Uimp): 8 kV\u003c\/p\u003e\n\u003cp data-start=\"1044\" data-end=\"1071\"\u003e\u003cstrong data-start=\"1044\" data-end=\"1071\"\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1073\" data-end=\"1206\"\u003e50 kA @ 230 V AC\u003cbr data-start=\"1089\" data-end=\"1092\"\u003e36 kA @ 400\/415 V AC\u003cbr data-start=\"1112\" data-end=\"1115\"\u003e25 kA @ 440 V AC\u003cbr data-start=\"1131\" data-end=\"1134\"\u003e20 kA @ 500 V AC\u003cbr data-start=\"1150\" data-end=\"1153\"\u003e5 kA @ 690 V AC\u003cbr data-start=\"1168\" data-end=\"1171\"\u003e36 kA @ 250 V DC\u003cbr data-start=\"1187\" data-end=\"1190\"\u003e36 kA @ 500 V DC\u003c\/p\u003e\n\u003cp data-start=\"1208\" data-end=\"1243\"\u003e\u003cstrong data-start=\"1208\" data-end=\"1243\"\u003eService Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1245\" data-end=\"1255\"\u003e75% of Icu\u003c\/p\u003e\n\u003cp data-start=\"1257\" data-end=\"1283\"\u003e\u003cstrong data-start=\"1257\" data-end=\"1283\"\u003e⚙️ Protection Settings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1285\" data-end=\"1312\"\u003e\u003cstrong data-start=\"1285\" data-end=\"1312\"\u003eThermal Protection (I1)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1314\" data-end=\"1350\"\u003eMin: 140 A\u003cbr data-start=\"1324\" data-end=\"1327\"\u003eMed: 170 A\u003cbr data-start=\"1337\" data-end=\"1340\"\u003eMax: 200 A\u003c\/p\u003e\n\u003cp data-start=\"1352\" data-end=\"1380\"\u003e\u003cstrong data-start=\"1352\" data-end=\"1380\"\u003eMagnetic Protection (I3)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1382\" data-end=\"1408\"\u003eInstantaneous Trip: 2000 A\u003c\/p\u003e\n\u003cp data-start=\"1410\" data-end=\"1438\"\u003e\u003cstrong data-start=\"1410\" data-end=\"1438\"\u003e🔧 Installed Accessories\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1440\" data-end=\"1638\"\u003eShunt Trip Release (SOR): 24...30 V AC\/DC\u003cbr data-start=\"1481\" data-end=\"1484\"\u003eAuxiliary Contacts (AUX - SY + Q): 250 V AC\/DC\u003cbr data-start=\"1530\" data-end=\"1533\"\u003eFactory-installed wiring, as shown in the photographs.\u003cbr data-start=\"1587\" data-end=\"1590\"\u003ePrepared for additional UVR and MOS accessories.\u003c\/p\u003e\n\u003cp data-start=\"1640\" data-end=\"1666\"\u003e\u003cstrong data-start=\"1640\" data-end=\"1666\"\u003e🛠 Mechanical Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1668\" data-end=\"1840\"\u003eInstallation: Fixed\u003cbr data-start=\"1687\" data-end=\"1690\"\u003eFront ON\/OFF Manual Operating Handle\u003cbr data-start=\"1726\" data-end=\"1729\"\u003eHeavy-duty construction for industrial applications.\u003cbr data-start=\"1781\" data-end=\"1784\"\u003ePower terminals suitable for large cross-section cables.\u003c\/p\u003e\n\u003cp data-start=\"1842\" data-end=\"1861\"\u003e\u003cstrong data-start=\"1842\" data-end=\"1861\"\u003e🏭 Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1863\" data-end=\"2055\"\u003e✔ Industrial electrical panels\u003cbr data-start=\"1893\" data-end=\"1896\"\u003e✔ Low-voltage power distribution\u003cbr data-start=\"1928\" data-end=\"1931\"\u003e✔ Industrial automation systems\u003cbr data-start=\"1962\" data-end=\"1965\"\u003e✔ Industrial machinery\u003cbr data-start=\"1987\" data-end=\"1990\"\u003e✔ Three-phase line protection\u003cbr data-start=\"2019\" data-end=\"2022\"\u003e✔ Photovoltaic and energy systems\u003c\/p\u003e\n\u003cp data-start=\"2057\" data-end=\"2080\"\u003e\u003cstrong data-start=\"2057\" data-end=\"2080\"\u003e📦 Package Contents\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2082\" data-end=\"2259\"\u003e1× ABB SACE Tmax T3N 250 3P 200A Circuit Breaker\u003cbr data-start=\"2130\" data-end=\"2133\"\u003eInstalled 24...30 V AC\/DC SOR Shunt Trip Release\u003cbr data-start=\"2181\" data-end=\"2184\"\u003eInstalled Auxiliary Contacts\u003cbr data-start=\"2212\" data-end=\"2215\"\u003eComplete wiring as shown in the photographs.\u003c\/p\u003e\n\u003cp data-start=\"2261\" data-end=\"2277\"\u003e\u003cstrong data-start=\"2261\" data-end=\"2277\"\u003e📦 Condition\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2279\" data-end=\"2393\"\u003eUsed product\u003cbr data-start=\"2291\" data-end=\"2294\"\u003eGood cosmetic condition\u003cbr data-start=\"2317\" data-end=\"2320\"\u003eComplete with the visible accessories\u003cbr data-start=\"2357\" data-end=\"2360\"\u003eSold as shown in the photographs.\u003c\/p\u003e\n\u003cp data-start=\"2395\" data-end=\"2828\"\u003e🚀 The ABB SACE Tmax T3N 250 is a professional molded case circuit breaker designed to provide reliable protection for industrial electrical installations. Equipped with a 24...30 V AC\/DC shunt trip release, auxiliary contacts, adjustable thermal-magnetic protection and a breaking capacity of up to 50 kA, it is an ideal solution for industrial distribution panels, automation systems and remote-controlled electrical installations.\u003c\/p\u003e\n\u003cp data-start=\"2830\" data-end=\"2853\"\u003e\u003cstrong data-start=\"2830\" data-end=\"2853\"\u003e✅ Technical Summary\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2855\" data-end=\"3257\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e✅ Brand: ABB SACE\u003cbr data-start=\"2872\" data-end=\"2875\"\u003e✅ Series: Tmax\u003cbr data-start=\"2889\" data-end=\"2892\"\u003e✅ Model: T3N 250\u003cbr data-start=\"2908\" data-end=\"2911\"\u003e✅ Type: Molded Case Circuit Breaker (MCCB)\u003cbr data-start=\"2953\" data-end=\"2956\"\u003e✅ Poles: 3P\u003cbr data-start=\"2967\" data-end=\"2970\"\u003e✅ Rated Current: 200 A\u003cbr data-start=\"2992\" data-end=\"2995\"\u003e✅ Rated Voltage: 690 V AC\u003cbr data-start=\"3020\" data-end=\"3023\"\u003e✅ Rated Insulation Voltage: 800 V\u003cbr data-start=\"3056\" data-end=\"3059\"\u003e✅ Rated Impulse Withstand Voltage: 8 kV\u003cbr data-start=\"3098\" data-end=\"3101\"\u003e✅ Breaking Capacity: Up to 50 kA\u003cbr data-start=\"3133\" data-end=\"3136\"\u003e✅ SOR Shunt Trip: 24...30 V AC\/DC\u003cbr data-start=\"3169\" data-end=\"3172\"\u003e✅ Auxiliary Contacts: 250 V AC\/DC\u003cbr data-start=\"3205\" data-end=\"3208\"\u003e✅ Standard: IEC 60947-2\u003cbr data-start=\"3231\" data-end=\"3234\"\u003e✅ Manufactured in Italy\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":54192473342285,"sku":null,"price":200.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_6325.jpg?v=1782920106","url":"https:\/\/greenenergy-repair.com\/cs\/products\/abb-sace-tmax-t3n-250-3-pole-200a-mccb-molded-case-circuit-breaker-with-sor-shunt-trip-auxiliary-contacts-690v-iec-60947-2","provider":"Green Energy","version":"1.0","type":"link"}