{"product_id":"abb-al16-30-10-power-contactor-3-pole-30-a-690-v-ac-dc-coil-1no-auxiliary-contact-iec-60947","title":"ABB AL16-30-10 Power Contactor | 3-Pole | 30 A | 690 V AC | DC Coil | 1NO Auxiliary Contact | IEC 60947","description":"\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"fbskMG_root markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eUsed product.\u003c\/strong\u003e The \u003cstrong\u003eABB AL16-30-10\u003c\/strong\u003e is a \u003cstrong\u003epower contactor\u003c\/strong\u003e from the ABB AL series, designed for switching and controlling \u003cstrong\u003ethree-phase electrical loads and motors\u003c\/strong\u003e in industrial applications.\u003c\/p\u003e\n\u003cp\u003eThe contactor features \u003cstrong\u003e3 main poles\u003c\/strong\u003e, clearly identified as \u003cstrong\u003e1L1–2T1, 3L2–4T2, and 5L3–6T3\u003c\/strong\u003e, together with an integrated \u003cstrong\u003e1NO auxiliary contact\u003c\/strong\u003e, identified by terminals \u003cstrong\u003e13NO–14NO\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe contactor belongs to the \u003cstrong\u003eABB AL series with a DC coil\u003c\/strong\u003e. The \u003cstrong\u003eAL16-30-10\u003c\/strong\u003e designation identifies the version with \u003cstrong\u003e1 normally open auxiliary contact\u003c\/strong\u003e. However, the complete coil voltage marking is not legible in the photographs. Since this series was available with different coil voltages, \u003cstrong\u003ethe exact coil voltage must be verified directly on the component before connection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe component shows \u003cstrong\u003enormal signs of previous use\u003c\/strong\u003e, including light abrasions and superficial marks on the plastic parts and terminals. Electrical operation cannot be certified from photographs alone; a test of the coil, main contacts, and auxiliary contact is recommended before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e AL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eAL16-30-10\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Power contactor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Main Poles:\u003c\/strong\u003e \u003cstrong\u003e3\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Contact Configuration:\u003c\/strong\u003e \u003cstrong\u003e3NO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contact:\u003c\/strong\u003e \u003cstrong\u003e1NO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional Free-Air Thermal Current Ith:\u003c\/strong\u003e \u003cstrong\u003e30 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated AC-1 Current:\u003c\/strong\u003e \u003cstrong\u003e30 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage Ui:\u003c\/strong\u003e \u003cstrong\u003e1000 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e up to \u003cstrong\u003e690 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilization Category:\u003c\/strong\u003e \u003cstrong\u003eAC-1 \/ AC-3\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Circuit Frequency:\u003c\/strong\u003e \u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil Type:\u003c\/strong\u003e \u003cstrong\u003eDC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eABB specifies an \u003cstrong\u003eAC-1 rating of 30 A\u003c\/strong\u003e for the AL16-30-10 and an \u003cstrong\u003eAC-3 current rating of 17 A at 415 V\u003c\/strong\u003e, corresponding to \u003cstrong\u003e7.5 kW\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cspan role=\"text\"\u003e\u003cstrong\u003eAC-3 Rated Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAccording to the values indicated for the unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e230 V:\u003c\/strong\u003e \u003cstrong\u003e4 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400 V:\u003c\/strong\u003e \u003cstrong\u003e7.5 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 V:\u003c\/strong\u003e \u003cstrong\u003e9 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e690 V:\u003c\/strong\u003e \u003cstrong\u003e9 kW\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AC-3 current rating varies according to voltage and operating conditions. For motor applications, the appropriate ABB rating table should therefore be used rather than relying only on the Ith value.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🔌 \u003cstrong\u003e1NO Auxiliary Contact\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe contactor features an integrated \u003cstrong\u003e13NO–14NO auxiliary contact\u003c\/strong\u003e, corresponding to the \u003cstrong\u003e1NO\u003c\/strong\u003e configuration of the AL16-30-10.\u003c\/p\u003e\n\u003cp\u003eAuxiliary contact specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e \u003cstrong\u003e1NO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtilization Category:\u003c\/strong\u003e AC-15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated AC-15 Current:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e4 A at 220\/240 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3 A at 380\/440 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2 A at 500 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2 A at 690 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Circuit Voltage:\u003c\/strong\u003e up to \u003cstrong\u003e690 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe auxiliary contact can be used for control, signaling, interlocking, and automation functions.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚡ \u003cstrong\u003eFunction in the Electrical System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB AL16-30-10\u003c\/strong\u003e is used for the \u003cstrong\u003eelectrical switching of three-phase loads\u003c\/strong\u003e, allowing the load supply to be controlled through a separate control circuit.\u003c\/p\u003e\n\u003cp\u003eThe three main contacts switch the three phases:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1L1 → 2T1\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3L2 → 4T2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5L3 → 6T3\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe integrated \u003cstrong\u003e13NO–14NO\u003c\/strong\u003e auxiliary contact can be used for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eContactor self-holding circuits\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eStatus indication\u003c\/li\u003e\n\u003cli\u003eElectrical interlocking\u003c\/li\u003e\n\u003cli\u003eControl circuits\u003c\/li\u003e\n\u003cli\u003eConnection to PLCs and automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ABB AL series uses \u003cstrong\u003elow-consumption DC coils\u003c\/strong\u003e, designed also for direct control from PLC outputs, depending on the specific coil-voltage version.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🏭 \u003cstrong\u003eConstruction \u0026amp; Installation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe contactor features a compact ABB construction designed for installation in \u003cstrong\u003eelectrical panels, automation cabinets, industrial machinery, and motor-control systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe construction includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e3 main power contacts\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003e1NO auxiliary contact\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eScrew terminals\u003c\/li\u003e\n\u003cli\u003eInsulating body suitable for industrial applications\u003c\/li\u003e\n\u003cli\u003eClearly identified front terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AL series is classified by ABB as \u003cstrong\u003eBlock Contactors\u003c\/strong\u003e and is available with different configurations and coil voltages.\u003c\/p\u003e\n\u003cp\u003e⚠️ \u003cstrong\u003eThe coil voltage must be verified directly on the component before energizing it.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🌐 \u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eDepending on the control voltage and operating conditions, the component may be used for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eThree-phase motor control\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIndustrial electrical panels\u003c\/li\u003e\n\u003cli\u003eIndustrial automation\u003c\/li\u003e\n\u003cli\u003ePumps\u003c\/li\u003e\n\u003cli\u003eFans\u003c\/li\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMaterial-handling systems\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery\u003c\/li\u003e\n\u003cli\u003eControl and power circuits\u003c\/li\u003e\n\u003cli\u003ePLC-controlled applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e💡 \u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eABB industrial construction\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3 main power poles\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e30 A AC-1\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e7.5 kW AC-3 at 400 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eUp to \u003cstrong\u003e9 kW AC-3\u003c\/strong\u003e at the indicated voltages\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUi 1000 V AC\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSuitable for applications up to \u003cstrong\u003e690 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIntegrated 1NO auxiliary contact\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eScrew terminals\u003c\/li\u003e\n\u003cli\u003eCompact design\u003c\/li\u003e\n\u003cli\u003eParticularly interesting as a \u003cstrong\u003ereplacement for existing ABB equipment\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong\u003eSafety \u0026amp; Product Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eUsed product\u003c\/strong\u003e, with visible cosmetic and usage marks consistent with previous installation.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, the following should be verified:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated coil voltage\u003c\/strong\u003e, which is not legible in the photographs\u003c\/li\u003e\n\u003cli\u003eCoil resistance\u003c\/li\u003e\n\u003cli\u003eCorrect mechanical operation\u003c\/li\u003e\n\u003cli\u003eContinuity of the three main contacts\u003c\/li\u003e\n\u003cli\u003eOperation of the \u003cstrong\u003e13NO–14NO\u003c\/strong\u003e auxiliary contact\u003c\/li\u003e\n\u003cli\u003eCondition and tightening of the terminals\u003c\/li\u003e\n\u003cli\u003eElectrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo not energize the coil before verifying its rated voltage.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation must be performed by \u003cstrong\u003equalified personnel\u003c\/strong\u003e, with the electrical system disconnected and in accordance with the component's rated specifications.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1 × ABB AL16-30-10 Power Contactor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1 × Integrated 1NO Auxiliary Contact\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe component is supplied in the configuration shown in the photographs.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🚀 \u003cstrong\u003eFinal Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB AL16-30-10\u003c\/strong\u003e is a compact industrial power contactor designed for \u003cstrong\u003eswitching three-phase loads\u003c\/strong\u003e, with a \u003cstrong\u003e30 A AC-1 rating\u003c\/strong\u003e, \u003cstrong\u003e17 A AC-3 at 415 V\u003c\/strong\u003e, and power up to \u003cstrong\u003e7.5 kW at 400 V\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe integrated \u003cstrong\u003e1NO auxiliary contact\u003c\/strong\u003e makes the contactor particularly versatile for control, self-holding, signaling, and automation circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e the \u003cstrong\u003ecoil voltage must not be stated as a confirmed value based on the available photographs alone\u003c\/strong\u003e. The AL16-30-10 family was available with different DC coil voltages, so the exact voltage must be verified directly from the component before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":54658138964301,"sku":null,"price":40.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_6562.jpg?v=1788532122","url":"https:\/\/greenenergy-repair.com\/cs\/products\/abb-al16-30-10-power-contactor-3-pole-30-a-690-v-ac-dc-coil-1no-auxiliary-contact-iec-60947","provider":"Green Energy","version":"1.0","type":"link"}