SolarMax Potentialausgleichsset | Article 2020-1 | PV Grounding Kit
Наличността за получаване на място не можа да се зареди
Discount
|
Spend €500+ |
3% OFF |
|---|---|
|
Spend €3 000+ |
5% OFF |
|
Spend €8 000+ |
10% OFF |
|
Spend €12 000+ |
Custom Quote |
Пазарувайте безопасно
Осигурете вашето пазаруване с различни безопасни и надеждни методи на плащане.
Smooth and stress-free — we handle issues, without bureaucracy.
From setup to questions — we’ve got your back after the sale.
Description
📝 Description
New product. The SolarMax Potentialausgleichsset (Article 2020-1) is an original SolarMax kit for equipotential bonding and grounding of the photovoltaic generator, intended for use with specific SolarMax inverters and systems. SolarMax documentation identifies the Potentialausgleichsset (PAS) as an accessory used for grounding the PV generator and also provides for monitoring of a possible PAS fuse interruption by the inverter.
⚙️ Technical Specifications
- Brand: SolarMax / Sputnik Engineering
- Type: Potentialausgleichsset / equipotential bonding kit
- Article: 2020-1
- Function: grounding of the photovoltaic generator
- Integrated electronic component: Analog Devices AD202JN – Isolation Amplifier
- Circuit: electronic board with isolation amplifier, resistors, capacitors, fuse and terminal blocks
- Connections: pre-wired harness with power/control conductors and terminal blocks
- Visible fuse: F2A
- AD202JN circuit isolation: up to 750 Vrms according to component specifications
- AD202JN power supply: +15 VDC, with an indicated operating range of approximately 13.5–16.5 VDC
- AD202JN operating temperature: −40…+85 °C
- Mounting: board inside a dedicated housing/support
-
Configuration: complete kit with original electronic board and wiring
The AD202JN used on the board is a galvanic isolation amplifier from Analog Devices, designed to transfer signals without a direct galvanic connection between input and output; the component is now classified as obsolete by the manufacturer/distributors.
⚡ Function in the Electrical System
ON-GRID photovoltaic system – PV generator and SolarMax inverter.
The Potentialausgleichsset (PAS) is used to establish the ground connection of the photovoltaic generator as part of the inverter's protection and control system. SolarMax documentation expressly specifies that the PAS is an accessory intended for grounding the PV generator.
The electronic circuit contained in the kit also allows the associated control-system signals to be electrically interfaced and isolated. The AD202JN is an isolation amplifier intended for signal measurement and isolation applications, including high-voltage instrumentation.
🏭 Construction and Installation
The kit consists of a pre-assembled SolarMax electronic board, mounted in a green support, with terminal blocks, wiring, fuse and protection/interface components. The photographs also show the pre-installed wiring and connection accessories included in the package.
The kit must be installed and connected exclusively according to the diagram specified for the compatible SolarMax inverter model. It should not be considered a universal grounding device for every photovoltaic system.
🛡️ Safety and Product Condition
New old-stock product, stored in the original SolarMax packaging. The contents appear complete and in good condition, with wiring and components present in the package. The box shows normal storage marks due to age.
The component is intended for electrical systems where dangerous DC voltages may be present. Installation, testing and connection must be carried out by qualified personnel. SolarMax documentation specifies that installation work on the relevant inverters must be performed by qualified electrical personnel.
📦 Package Contents
- 1 × SolarMax Potentialausgleichsset
- Article 2020-1
- Electronic board with Analog Devices AD202JN
- Pre-installed wiring
- Terminals and accessories visible in the photographs
- Original SolarMax packaging
🚀 Final Description
The SolarMax Potentialausgleichsset (Article 2020-1) is an original kit for equipotential bonding and grounding of the photovoltaic generator, intended for specific SolarMax inverter configurations. The presence of the electronic board with AD202JN Isolation Amplifier, F2A fuse, terminal blocks and pre-installed wiring identifies a technical assembly specifically designed for integration into the SolarMax system. TS series documentation confirms the function of the PAS as an accessory for grounding the PV generator.
Got a question?
Don't be a stranger.

Пазарувайте безопасно
В нашия магазин Shopify даваме приоритет на вашата безопасност и сигурност. Ето как гарантираме сигурно пазаруване:
1. Сигурни транзакции: Ние използваме разширено криптиране, за да защитим вашата лична информация и информация за плащане, като гарантираме, че тя е безопасно предадена и защитена.
2. Доверени шлюзове за плащане: Нашият магазин се интегрира с доверени шлюзове за плащане, като гарантира, че вашите транзакции се обработват сигурно и ефективно.
3. Поверителност на данните: Вашата поверителност е наш основен приоритет. Ние следваме стриктни политики за защита на данните, за да запазим поверителността и сигурността на вашата лична информация.
4. Сигурна платформа: Shopify предоставя стабилни функции за сигурност и непрекъснато наблюдение срещу уязвимости, като гарантира безопасна среда за пазаруване.
5. Проверени търговци: Ние сме проверен търговец на Shopify, ангажиран с предоставянето на автентични и висококачествени продукти.
6. Прозрачни политики: Нашите ясни политики за връщане, възстановяване на средства и доставка осигуряват спокойствие, знаейки, че стоим зад нашите продукти.
7. Поддръжка на клиенти: Нашият специален екип за поддръжка на клиенти е готов да ви помогне с всякакви притеснения или въпроси, които може да имате.
Пазарувайте уверено в нашия магазин Shopify, където вашата безопасност и удовлетворение са нашите основни приоритети.
🔒 Warranty Terms and Conditions
By placing an order, you acknowledge and agree to the following warranty policy:
✅ 1-Year Warranty for Inverters
- All solar inverter units come with a 1-year warranty from the date of purchase.
- Each unit is fully inspected and tested before shipment to ensure proper functionality.
🔧 What the Warranty Covers
- The warranty covers defects and malfunctions that occur during standard operation.
- This includes the inverter as a whole and its internal components and circuit boards.
- If any issue arises within the warranty period, we will repair or replace the defective part or product, in line with our warranty policy.
🛠 Warranty for Separate Components
- For individual internal circuit boards, components, and repair kits ordered separately, a 6-month warranty applies from the date of purchase.
- Within this period, any functional failure will result in a free replacement as per our warranty terms.
⚠️ What the Warranty Does Not Cover
- The warranty does not apply in the following cases
- Improper installation by the customer or third parties
- Network overvoltage
- Lightning strikes or other environmental/external damage
❗ Please ensure correct installation by a qualified technician. Improper connection or handling voids the warranty.
€180,00 EUR