{"product_id":"solar-log-1200-gprs-data-logger-pv-monitoring-system-gsm-gprs-lcd-display-multi-inverter","title":"Solar-Log 1200 GPRS – Data Logger | PV Monitoring System | GSM\/GPRS | LCD Display | Multi-Inverter","description":"\u003cp data-start=\"146\" data-end=\"325\"\u003eThe \u003cstrong data-start=\"150\" data-end=\"173\"\u003eSolar-Log 1200 GPRS\u003c\/strong\u003e is a professional \u003cstrong data-start=\"192\" data-end=\"232\"\u003edata logger for photovoltaic systems\u003c\/strong\u003e, designed for monitoring, data acquisition, and remote transmission of inverter performance.\u003c\/p\u003e\n\u003cp data-start=\"327\" data-end=\"496\"\u003eThis device acts as a \u003cstrong data-start=\"349\" data-end=\"376\"\u003ecentral monitoring unit\u003c\/strong\u003e, enabling continuous supervision of energy production and system status, with remote access via \u003cstrong data-start=\"473\" data-end=\"495\"\u003eGPRS communication\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"498\" data-end=\"661\"\u003eEquipped with an integrated display, communication interfaces, and digital inputs, it is suitable for \u003cstrong data-start=\"600\" data-end=\"660\"\u003eresidential, commercial, and industrial PV installations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"663\" data-end=\"666\"\u003e\n\u003ch3 data-start=\"668\" data-end=\"689\"\u003e⚙️ Main Functions\u003c\/h3\u003e\n\u003cul data-start=\"690\" data-end=\"1051\"\u003e\n\u003cli data-start=\"690\" data-end=\"752\"\u003eMonitoring of energy production (\u003cstrong data-start=\"725\" data-end=\"749\"\u003ekWh, real-time power\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-start=\"753\" data-end=\"797\"\u003eData acquisition from multiple inverters\u003c\/li\u003e\n\u003cli data-start=\"798\" data-end=\"858\"\u003eRemote data transmission via \u003cstrong data-start=\"829\" data-end=\"856\"\u003eGPRS (cellular network)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"859\" data-end=\"909\"\u003eLocal visualization through integrated display\u003c\/li\u003e\n\u003cli data-start=\"910\" data-end=\"962\"\u003eHistorical data logging and performance analysis\u003c\/li\u003e\n\u003cli data-start=\"963\" data-end=\"994\"\u003eFault and anomaly detection\u003c\/li\u003e\n\u003cli data-start=\"995\" data-end=\"1051\"\u003eInterface with sensors and energy meters (S0 inputs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1053\" data-end=\"1056\"\u003e\n\u003ch3 data-start=\"1058\" data-end=\"1089\"\u003e🔌 Technical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1090\" data-end=\"1164\"\u003e\n\u003cli data-start=\"1090\" data-end=\"1124\"\u003eModel: \u003cstrong data-start=\"1099\" data-end=\"1122\"\u003eSolar-Log 1200 GPRS\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1125\" data-end=\"1164\"\u003ePower supply: \u003cstrong data-start=\"1141\" data-end=\"1162\"\u003e12 V DC – max 1 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1166\" data-end=\"1184\"\u003e\u003cstrong data-start=\"1166\" data-end=\"1184\"\u003eCommunication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1185\" data-end=\"1218\"\u003e\n\u003cli data-start=\"1185\" data-end=\"1205\"\u003eGPRS (SIM-based)\u003c\/li\u003e\n\u003cli data-start=\"1206\" data-end=\"1218\"\u003eUSB port\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1220\" data-end=\"1239\"\u003e\u003cstrong data-start=\"1220\" data-end=\"1239\"\u003eDigital Inputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1240\" data-end=\"1308\"\u003e\n\u003cli data-start=\"1240\" data-end=\"1279\"\u003eS0 IN \/ OUT (pulse meter interface)\u003c\/li\u003e\n\u003cli data-start=\"1280\" data-end=\"1308\"\u003eMax: \u003cstrong data-start=\"1287\" data-end=\"1306\"\u003e27 V \/ 27 mA DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1310\" data-end=\"1322\"\u003e\u003cstrong data-start=\"1310\" data-end=\"1322\"\u003eDisplay:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1323\" data-end=\"1364\"\u003e\n\u003cli data-start=\"1323\" data-end=\"1364\"\u003eIntegrated LCD for data visualization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1366\" data-end=\"1385\"\u003e\u003cstrong data-start=\"1366\" data-end=\"1385\"\u003eOther Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1386\" data-end=\"1498\"\u003e\n\u003cli data-start=\"1386\" data-end=\"1402\"\u003eRESET button\u003c\/li\u003e\n\u003cli data-start=\"1403\" data-end=\"1448\"\u003eExternal antenna connector for GSM signal\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1478\"\u003eWall-mounted installation\u003c\/li\u003e\n\u003cli data-start=\"1479\" data-end=\"1498\"\u003eMade in Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1500\" data-end=\"1503\"\u003e\n\u003ch3 data-start=\"1505\" data-end=\"1523\"\u003e🌐 System Role\u003c\/h3\u003e\n\u003cp data-start=\"1525\" data-end=\"1577\"\u003eWithin a photovoltaic system, the Solar-Log acts as:\u003c\/p\u003e\n\u003cul data-start=\"1578\" data-end=\"1731\"\u003e\n\u003cli data-start=\"1578\" data-end=\"1611\"\u003eData collector from inverters\u003c\/li\u003e\n\u003cli data-start=\"1612\" data-end=\"1643\"\u003eProcessing and storage unit\u003c\/li\u003e\n\u003cli data-start=\"1644\" data-end=\"1686\"\u003eGateway to remote monitoring platforms\u003c\/li\u003e\n\u003cli data-start=\"1687\" data-end=\"1731\"\u003eDiagnostic and performance analysis tool\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1733\" data-end=\"1799\"\u003e👉 Essentially, it is the \u003cstrong data-start=\"1759\" data-end=\"1798\"\u003e“monitoring brain” of the PV system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1801\" data-end=\"1804\"\u003e\n\u003ch3 data-start=\"1806\" data-end=\"1828\"\u003e🧩 Main Components\u003c\/h3\u003e\n\u003cul data-start=\"1829\" data-end=\"2039\"\u003e\n\u003cli data-start=\"1829\" data-end=\"1850\"\u003eFront LCD display\u003c\/li\u003e\n\u003cli data-start=\"1851\" data-end=\"1890\"\u003eGPRS module with antenna connection\u003c\/li\u003e\n\u003cli data-start=\"1891\" data-end=\"1926\"\u003eS0 interfaces for energy meters\u003c\/li\u003e\n\u003cli data-start=\"1927\" data-end=\"1957\"\u003eUSB port for configuration\u003c\/li\u003e\n\u003cli data-start=\"1958\" data-end=\"1989\"\u003eData processing electronics\u003c\/li\u003e\n\u003cli data-start=\"1990\" data-end=\"2013\"\u003e12 V DC power input\u003c\/li\u003e\n\u003cli data-start=\"2014\" data-end=\"2039\"\u003eHardware reset button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2041\" data-end=\"2044\"\u003e\n\u003ch3 data-start=\"2046\" data-end=\"2067\"\u003e⚠️ Typical Faults\u003c\/h3\u003e\n\u003cul data-start=\"2068\" data-end=\"2235\"\u003e\n\u003cli data-start=\"2068\" data-end=\"2098\"\u003eGPRS communication failure\u003c\/li\u003e\n\u003cli data-start=\"2099\" data-end=\"2123\"\u003eNo data transmission\u003c\/li\u003e\n\u003cli data-start=\"2124\" data-end=\"2147\"\u003eDisplay malfunction\u003c\/li\u003e\n\u003cli data-start=\"2148\" data-end=\"2175\"\u003eLoss of historical data\u003c\/li\u003e\n\u003cli data-start=\"2176\" data-end=\"2209\"\u003eInverter communication errors\u003c\/li\u003e\n\u003cli data-start=\"2210\" data-end=\"2235\"\u003eIssues with S0 inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2237\" data-end=\"2240\"\u003e\n\u003ch3 data-start=\"2242\" data-end=\"2270\"\u003e🚨 Problems It Can Solve\u003c\/h3\u003e\n\u003cp data-start=\"2271\" data-end=\"2303\"\u003eReplacing this unit can resolve:\u003c\/p\u003e\n\u003cul data-start=\"2304\" data-end=\"2469\"\u003e\n\u003cli data-start=\"2304\" data-end=\"2333\"\u003eMissing system monitoring\u003c\/li\u003e\n\u003cli data-start=\"2334\" data-end=\"2366\"\u003eNo data on Solar-Log portals\u003c\/li\u003e\n\u003cli data-start=\"2367\" data-end=\"2400\"\u003eRemote communication failures\u003c\/li\u003e\n\u003cli data-start=\"2401\" data-end=\"2437\"\u003eInverter data acquisition issues\u003c\/li\u003e\n\u003cli data-start=\"2438\" data-end=\"2469\"\u003eProduction logging problems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2471\" data-end=\"2474\"\u003e\n\u003ch3 data-start=\"2476\" data-end=\"2496\"\u003e🏭 Compatibility\u003c\/h3\u003e\n\u003cul data-start=\"2497\" data-end=\"2698\"\u003e\n\u003cli data-start=\"2497\" data-end=\"2606\"\u003eMulti-brand inverter compatibility:\n\u003cul data-start=\"2539\" data-end=\"2606\"\u003e\n\u003cli data-start=\"2539\" data-end=\"2558\"\u003eABB \/ Power-One\u003c\/li\u003e\n\u003cli data-start=\"2561\" data-end=\"2568\"\u003eSMA\u003c\/li\u003e\n\u003cli data-start=\"2571\" data-end=\"2579\"\u003eKACO\u003c\/li\u003e\n\u003cli data-start=\"2582\" data-end=\"2593\"\u003eFronius\u003c\/li\u003e\n\u003cli data-start=\"2596\" data-end=\"2606\"\u003eOthers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2608\" data-end=\"2662\"\u003eSuitable for residential and industrial PV systems\u003c\/li\u003e\n\u003cli data-start=\"2663\" data-end=\"2698\"\u003eCompatible with S0 pulse meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2700\" data-end=\"2703\"\u003e\n\u003ch3 data-start=\"2705\" data-end=\"2724\"\u003e📊 Applications\u003c\/h3\u003e\n\u003cul data-start=\"2725\" data-end=\"2858\"\u003e\n\u003cli data-start=\"2725\" data-end=\"2759\"\u003ePhotovoltaic system monitoring\u003c\/li\u003e\n\u003cli data-start=\"2760\" data-end=\"2794\"\u003eRemote supervision and control\u003c\/li\u003e\n\u003cli data-start=\"2795\" data-end=\"2826\"\u003eMaintenance and diagnostics\u003c\/li\u003e\n\u003cli data-start=\"2827\" data-end=\"2858\"\u003eEnergy performance analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2860\" data-end=\"2863\"\u003e\n\u003ch3 data-start=\"2865\" data-end=\"2889\"\u003e📦 Product Condition\u003c\/h3\u003e\n\u003cul data-start=\"2890\" data-end=\"3075\"\u003e\n\u003cli data-start=\"2890\" data-end=\"2931\"\u003eComplete \u003cstrong data-start=\"2901\" data-end=\"2924\"\u003eSolar-Log 1200 GPRS\u003c\/strong\u003e unit\u003c\/li\u003e\n\u003cli data-start=\"2932\" data-end=\"2954\"\u003eUsed \/ refurbished\u003c\/li\u003e\n\u003cli data-start=\"2955\" data-end=\"3007\"\u003eAccessories included (manuals \/ CD if available)\u003c\/li\u003e\n\u003cli data-start=\"3008\" data-end=\"3034\"\u003eTested (if applicable)\u003c\/li\u003e\n\u003cli data-start=\"3035\" data-end=\"3075\"\u003eSold as professional technical spare\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3077\" data-end=\"3080\"\u003e\n\u003ch3 data-start=\"3082\" data-end=\"3096\"\u003e💡 Summary\u003c\/h3\u003e\n\u003cp data-start=\"3098\" data-end=\"3282\"\u003eThe \u003cstrong data-start=\"3102\" data-end=\"3125\"\u003eSolar-Log 1200 GPRS\u003c\/strong\u003e is an advanced \u003cstrong data-start=\"3141\" data-end=\"3174\"\u003eremote monitoring data logger\u003c\/strong\u003e for photovoltaic systems, essential for performance tracking, diagnostics, and efficient energy management.\u003c\/p\u003e","brand":"Green Energy","offers":[{"title":"Default Title","offer_id":53805634748749,"sku":null,"price":600.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_5521.jpg?v=1777472933","url":"https:\/\/greenenergy-repair.com\/bg\/products\/solar-log-1200-gprs-data-logger-pv-monitoring-system-gsm-gprs-lcd-display-multi-inverter","provider":"Green Energy","version":"1.0","type":"link"}