{"product_id":"schaffner-fn258p-42-33-3-phase-emc-filter-42-a","title":"Schaffner FN258P-42-33 | 3-Phase EMC Filter | 42 A","description":"\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eUsed product.\u003c\/strong\u003e The \u003cstrong\u003eSchaffner FN258P-42-33\u003c\/strong\u003e is a \u003cstrong\u003etwo-stage 3-phase EMC\/RFI filter\u003c\/strong\u003e, designed to suppress conducted electromagnetic interference in industrial power applications. The model is clearly identified on the nameplate as \u003cstrong\u003eFN258P-42-33\u003c\/strong\u003e, with production \u003cstrong\u003eMade in Thailand\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe nameplate shows \u003cstrong\u003e3×480\/275 V – 50\/60 Hz\u003c\/strong\u003e and \u003cstrong\u003e42 A @ 50 °C\u003c\/strong\u003e. The configuration is 3-phase \u003cstrong\u003eDelta\u003c\/strong\u003e, with \u003cstrong\u003eLINE\u003c\/strong\u003e input and \u003cstrong\u003eLOAD\u003c\/strong\u003e output connections on \u003cstrong\u003eL1, L2, L3 and PE\u003c\/strong\u003e, respectively.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schaffner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eFN258P-42-33\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e \u003cstrong\u003e3-phase EMC\/RFI mains filter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e \u003cstrong\u003eThree Phase – Delta\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnology:\u003c\/strong\u003e \u003cstrong\u003eTwo-stage\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e \u003cstrong\u003e42 A @ 50 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e \u003cstrong\u003e3×480\/275 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e \u003cstrong\u003e50–60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e \u003cstrong\u003eLINE – L1, L2, L3, PE\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e \u003cstrong\u003eLOAD – L1', L2', L3', PE\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Chassis\/panel mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e \u003cstrong\u003e−25…+100 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlammability rating:\u003c\/strong\u003e \u003cstrong\u003eUL94 V-0\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e \u003cstrong\u003eCSA, ENEC, UR\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing:\u003c\/strong\u003e \u003cstrong\u003eMade in Thailand\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprox. dimensions:\u003c\/strong\u003e \u003cstrong\u003e329 × 70 × 185 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚡ \u003cstrong\u003eFunction in the Electrical System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe filter is installed \u003cstrong\u003ein series on the 3-phase line\u003c\/strong\u003e, between the power supply and the connected equipment. The \u003cstrong\u003etwo-stage\u003c\/strong\u003e technology attenuates \u003cstrong\u003econducted electromagnetic interference\u003c\/strong\u003e, reducing the propagation toward the electrical network of interference generated by electronic equipment. It is particularly suitable for \u003cstrong\u003einverters, converters, motor drives, and industrial power systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🏭 \u003cstrong\u003eConstruction \u0026amp; Installation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe component features a \u003cstrong\u003erobust shielding metal housing\u003c\/strong\u003e with separate 3-phase terminals for input and output. The photographs clearly show the \u003cstrong\u003eLINE\u003c\/strong\u003e and \u003cstrong\u003eLOAD\u003c\/strong\u003e markings, with identification of the three phases \u003cstrong\u003eL1, L2, and L3\u003c\/strong\u003e. A \u003cstrong\u003ePE\u003c\/strong\u003e connection with its corresponding earth conductor is also present.\u003c\/p\u003e\n\u003cp\u003eThe nameplate carries the warning \u003cstrong\u003e“HIGH LEAKAGE CURRENT – first connect to earth!”\u003c\/strong\u003e. The \u003cstrong\u003ePE must therefore be connected before the power conductors\u003c\/strong\u003e. The terminals must be correctly tightened according to the manufacturer's instructions.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🌐 \u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFN258P-42-33\u003c\/strong\u003e is suitable for \u003cstrong\u003e3-phase inverters, power converters, Power Drive Systems, industrial drives, automation systems, industrial power supplies, and electrical switchboards\u003c\/strong\u003e where proper EMC interference management is required.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong\u003eSafety \u0026amp; Product Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe component is \u003cstrong\u003eused\u003c\/strong\u003e, with \u003cstrong\u003enormal installation marks, superficial scratches, and handling traces\u003c\/strong\u003e on the metal housing and terminals. No significant structural breaks are evident in the photographs. \u003cstrong\u003eElectrical operation is not declared without specific testing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBefore installation, it is recommended to verify \u003cstrong\u003einsulation, PE continuity, terminal integrity, correct tightening, and filter attenuation\u003c\/strong\u003e. As it is intended for \u003cstrong\u003e480 VAC and 42 A\u003c\/strong\u003e, it must be installed exclusively by qualified personnel.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1 × Schaffner FN258P-42-33\u003c\/strong\u003e, \u003cstrong\u003e42 A 3-phase EMC\/RFI filter\u003c\/strong\u003e, complete with metal housing, terminals, and PE connection as shown in the photographs.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🚀 \u003cstrong\u003eFinal Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchaffner FN258P-42-33\u003c\/strong\u003e is a professional \u003cstrong\u003e42 A 3-phase industrial EMC filter\u003c\/strong\u003e, with \u003cstrong\u003e3×480\/275 V\u003c\/strong\u003e voltage, \u003cstrong\u003e50–60 Hz\u003c\/strong\u003e frequency, and \u003cstrong\u003etwo-stage\u003c\/strong\u003e technology. The \u003cstrong\u003eDelta\u003c\/strong\u003e configuration and design for industrial power applications make it particularly interesting as a \u003cstrong\u003ereplacement for inverters, drives, and converters\u003c\/strong\u003e. The model is currently of limited availability on the market, increasing the interest of the component as a \u003cstrong\u003eused industrial replacement part\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Schaffner Filter","offers":[{"title":"Default Title","offer_id":54702183711053,"sku":null,"price":120.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_6736.jpg?v=1788970225","url":"https:\/\/greenenergy-repair.com\/bg\/products\/schaffner-fn258p-42-33-3-phase-emc-filter-42-a","provider":"Green Energy","version":"1.0","type":"link"}