{"product_id":"schaffner-fn2200b-150-40-dc-emc-filter-150-a","title":"Schaffner FN2200B-150-40 | DC EMC Filter | 150 A","description":"\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"fbskMG_root markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eUsed product.\u003c\/strong\u003e \u003cstrong\u003eSchaffner FN2200B-150-40 EMC\/RFI filter\u003c\/strong\u003e, designed for \u003cstrong\u003ehigh-voltage DC circuits\u003c\/strong\u003e, particularly for \u003cstrong\u003ephotovoltaic inverters\u003c\/strong\u003e. The model is identified by the manufacturer with \u003cstrong\u003eSAP code 803516\u003c\/strong\u003e and is specified for \u003cstrong\u003e150 A and maximum 1200 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚙️ \u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSchaffner FN2200B-150-40\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSchaffner\/SAP code: \u003cstrong\u003e803516\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1-stage DC EMC\/RFI filter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMaximum voltage: \u003cstrong\u003e1200 VDC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRated current: \u003cstrong\u003e150 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV-FIELD → INVERTER\u003c\/strong\u003e connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+ \/ −\u003c\/strong\u003e polarity and \u003cstrong\u003ePE\u003c\/strong\u003e connection\u003c\/li\u003e\n\u003cli\u003eConnections via \u003cstrong\u003escrew terminals\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis\u003c\/strong\u003e mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNatural convection\u003c\/strong\u003e cooling\u003c\/li\u003e\n\u003cli\u003eOperating temperature: \u003cstrong\u003e−40…+100 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eOvervoltage category \u003cstrong\u003eII\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePollution degree \u003cstrong\u003ePD2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDimensions approx. \u003cstrong\u003e250 × 140 × 115 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eWeight approx. \u003cstrong\u003e4.9 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOverload capacity: \u003cstrong\u003e4× rated current at startup\u003c\/strong\u003e and \u003cstrong\u003e1.5× for 1 minute\u003c\/strong\u003e, once per hour.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e⚡ \u003cstrong\u003eFunction in the Electrical System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFN2200B\u003c\/strong\u003e is installed between the \u003cstrong\u003ephotovoltaic field and the inverter\u003c\/strong\u003e to reduce \u003cstrong\u003ehigh-frequency conducted emissions\u003c\/strong\u003e on the DC side and limit interference that could propagate toward the PV modules. The filter also helps protect the panels from \u003cstrong\u003eHF leakage currents\u003c\/strong\u003e, which can contribute to premature aging of the modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🏭 \u003cstrong\u003eIdentification and Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe photographed nameplate clearly shows:\u003cbr\u003e\u003cstrong\u003eFN2200B-150-40\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003emax. 1200VDC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e150A @ 55°C\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e40\/100\/21\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e6034109 – 06 – 1025R\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003ePV-FIELD\u003c\/strong\u003e, \u003cstrong\u003eINVERTER\u003c\/strong\u003e, \u003cstrong\u003e+\u003c\/strong\u003e, \u003cstrong\u003e−\u003c\/strong\u003e, and \u003cstrong\u003ePE\u003c\/strong\u003e indications are also visible, with a \u003cstrong\u003erecommended tightening torque of 17–20 Nm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🛡️ \u003cstrong\u003eSafety and Product Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe component shows \u003cstrong\u003enormal signs of use and installation\u003c\/strong\u003e, with light abrasions on the metal housing. Functionality is not declared without specific testing.\u003cbr\u003e⚠️ \u003cstrong\u003e1200 VDC \/ 150 A:\u003c\/strong\u003e component for high-voltage, high-power photovoltaic circuits. Connection must be carried out exclusively by qualified personnel, respecting \u003cstrong\u003epolarity, PV-FIELD\/INVERTER direction, PE, and tightening torque\u003c\/strong\u003e. Dangerous DC voltages may be present even when the system appears to be switched off.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e📦 \u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003eSchaffner FN2200B-150-40\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCode \u003cstrong\u003e803516\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eUsed component in the condition visible in the photographs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan role=\"text\"\u003e🚀 \u003cstrong\u003eFinal Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSchaffner FN2200B-150-40\u003c\/strong\u003e, \u003cstrong\u003e150 A \/ 1200 VDC DC EMC\/RFI filter\u003c\/strong\u003e, specifically designed for \u003cstrong\u003ephotovoltaic inverters and high-power DC conversion systems\u003c\/strong\u003e. It is an industrial-grade component with power terminals and a metal housing for chassis mounting. The model is still identified by distributors as a \u003cstrong\u003e150 A, 1200 VDC, single-stage Schaffner DC filter\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schaffner Filter","offers":[{"title":"Default Title","offer_id":54730141630797,"sku":null,"price":220.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_6815.jpg?v=1789397912","url":"https:\/\/greenenergy-repair.com\/bg\/products\/schaffner-fn2200b-150-40-dc-emc-filter-150-a","provider":"Green Energy","version":"1.0","type":"link"}