{"product_id":"epcos-sifi-h-b84113h0000b030-emi-emc-mains-filter-250-v-3-a","title":"EPCOS SIFI-H B84113H0000B030 | EMI\/EMC Mains Filter | 250 V | 3 A","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eUsed product. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEPCOS (TDK) SIFI-H series mains interference filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, model \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eB84113H0000B030\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, designed for EMI\/EMC filtering applications on single-phase power supplies.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIt is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-line mains filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, developed to provide high attenuation of conducted electromagnetic interference. Its construction incorporates filtering inductors and capacitors inside a compact metal enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003e📋 Official Technical Data\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EPCOS \/ TDK\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSeries:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e B84113H – SIFI-H\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel code:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e B84113H0000B030\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eType:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Single-phase, two-line EMI\/EMC filter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRated voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 250 V AC\/DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRated current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFrequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRated temperature indicated on the label:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e TR = 40 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eClimatic category:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25\/100\/21\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInductors:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4 × 5.9 mH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eX2 capacitors:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2 × 1 µF\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eY2 capacitors:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2 × 4.7 nF\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDischarge resistor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 340 kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003e🔧 Main Functions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAttenuation of conducted electromagnetic interference on the power supply line.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFiltering of EMI interference entering and leaving connected equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eImproved electromagnetic compatibility (EMC) of connected devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTwo-stage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e filtering configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003e🔌 Connections and Components\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower input marked \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLINE\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOutput to equipment marked \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLOAD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnections for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elive (L\/L')\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eneutral (N\/N')\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eprotective earth (PE)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMetal blade terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInternal circuit with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eX2 and Y2 class\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e inductors and capacitors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003e🧱 Materials and Construction Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShielded metal enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for chassis mounting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInternal polyurethane encapsulation, as specified in the series documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for applications requiring high levels of interference attenuation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003e🏭 Applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAccording to official EPCOS\/TDK documentation, this series is intended for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSwitching power supplies.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTelecommunications systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eData processing systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003e📦 Product Condition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eUsed component, with cosmetic marks and signs of wear on the metal enclosure. The rated specifications listed above are taken from the label and the manufacturer's technical documentation. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eOperation has not been declared as tested.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003e🛒 Sale Includes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × EPCOS SIFI-H B84113H0000B030 mains filter.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eSummary\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEPCOS SIFI-H B84113H0000B030 mains filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, single-phase, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e250 V AC\/DC, 3 A, 50\/60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, featuring two-stage EMI\/EMC filtering, a metal enclosure and LINE\/LOAD connections.\u003c\/span\u003e\u003c\/p\u003e","brand":"EPCOS","offers":[{"title":"Default Title","offer_id":55355149222221,"sku":null,"price":15.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/3274\/3245\/files\/MG_7433.jpg?v=1794324337","url":"https:\/\/greenenergy-repair.com\/bg\/products\/epcos-sifi-h-b84113h0000b030-emi-emc-mains-filter-250-v-3-a","provider":"Green Energy","version":"1.0","type":"link"}